[powernet] DMC2000GN

2016-04-28 Thread Bradley A Krupp
Fermi would like to talk with anyone who has used the DMC2000GN with version 1.08.04 of Sentinel. Please provide contact information. Thanks in advance for your assistance. Brad Krupp

[powernet] Delivering the Nuclear Promise Radworker Requal qualification date frequencies

2016-08-18 Thread Bradley A Krupp
>From what I understand from the "Delivering the Nuclear Promise: In-processing >Focus" Webinar the Rad Worker requal frequencies are going to be different for >utility workers and supplemental workers. Rad Worker training for utility >workers is supposed to be good for 4 years and 2 years for

[powernet] telemetry software latency

2016-10-17 Thread Bradley A Krupp
Fermi 2 is looking for feedback from peers on how much latency (time delay from when a dosimeter is in a dose rate field to when the dose rate and workers dose is displayed on the computer screen) they are seeing in their telemetry systems and what you may have done to improve it. We know

[powernet] Iodine cartridges

2017-06-27 Thread Bradley A Krupp
Fermi would like to know what type of iodine cartridges (silver zeoilite, charcoal) our peers our using for emergency response and why. Thanks in advance for your assistance. Brad Krupp

[powernet] GEDDS and VSDS

2018-03-26 Thread Bradley A Krupp
Fermi is in the process of implementing S technologies GEDDS and VSDS software. We are looking for feedback from peers on their implementations. We are particularly interested in where (corporate or onsite) your GEDDS and VSDS servers are located and why. Please provide a point of contact

Re: [Powernet] [EXTERNAL] Test Post

2018-09-27 Thread Bradley A Krupp via Powernet
hello -Original Message- From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Linda Sewell via Powernet Sent: Thursday, September 27, 2018 10:21 AM To: powernet@hpspowernet.org Cc: Linda Sewell Subject: [EXTERNAL] [Powernet] Test Post Hi All, I haven’t seen any posts

Re: [Powernet] Quick Benchmarking on ED's

2018-10-31 Thread Bradley A Krupp via Powernet
Fermi 2 Using a mix of DMC2000S and DMC3000. DMC2000's are used primarily for remote monitoring. DMC3000's are used for everything else. Once we upgrade our telemetry software (currently using TeleView 2000 but we own but have not implemented GEDDS) we plan on phasing out the use of

[Powernet] VSDS

2019-01-23 Thread Bradley A Krupp via Powernet
Fermi is in the process of evaluating implementing use of S Technologies VSDS (Visual Survey Data System). We are wondering if anyone would be willing to share any work instruction, procedure, or job aids they may have for use of VSDS at their facility. Thanks in advance for your assistance.

[Powernet] GEDDS procedures

2018-11-26 Thread Bradley A Krupp via Powernet
Fermi is in the processing of implementing the use of S Technologies GEDDS (Graphical Electronic Dosimetry Display System). We are wondering if anyone would be willing to share their work instructions or procedures for using the software and any associated administrative functions. Thanks in

[Powernet] Landauer Verifii digital dosimetry platform

2019-01-09 Thread Bradley A Krupp via Powernet
We have been asked to evaluate whether the Landauer Verifii digital dosimetry platform would be of any value to implement at Fermi 2. We currently use the Landauer Inlight Model 2 for our DLR along with Sentinel. Mirion DMC2000's and 3000's are used as SRDs along with the applicable

Re: [Powernet] sending Form 5s and requesting Form 5 using email instead of FAX

2019-03-21 Thread Bradley A Krupp via Powernet
Fermi is not at this time -Original Message- From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Macho, Michael via Powernet Sent: Wednesday, March 20, 2019 3:51 PM To: powernet@HPSpowernet.org; powernet-boun...@hpspowernet.org Cc: Macho, Michael Subject: [EXTERNAL]

Re: [Powernet] [EXTERNAL] Fixed Radiation Monitoring System calibration question

2019-01-29 Thread Bradley A Krupp via Powernet
At Fermi 2, the RP Dept has a separate group of instrument personnel that are fully qualified RP techs. This affords them the ability to handle sources, post areas, etc. as necessary. They are responsible for both tech spec and non tech spec rad monitor calibrations (GE, Gulf Atomic)

Re: [Powernet] [EXTERNAL] High Range Noble Gas Monitors

2019-06-05 Thread Bradley A Krupp via Powernet
Fermi 2 recently upgraded to using GEDDS as our telemetry software. We have been able to set up AMS-4s in GEDDS. Theses have just been the standard particulate units. My question has to do with a unit set up for Noble gas. We are able to configure it in GEDDS but don’t understand if there

[Powernet] GEDDS and VSDS

2019-06-24 Thread Bradley A Krupp via Powernet
Fermi has recently implemented GEDDS and VSDS. Would like to talk peers on how they have set up their failover process for if their primary database or application server has gone down. Thanks in advance for your assistance. Brad Krupp ___ Powernet

Re: [Powernet] [EXTERNAL] Has another utility experienced unusual neutron spikes response when using DMC2000GN dosimeters

2019-04-29 Thread Bradley A Krupp via Powernet
Fermi has limited experience with the DMC2000GN. Planning on using them during Dry Cask Storage for monitoring Neutron only. From: Powernet [mailto:powernet-boun...@hpspowernet.org] On Behalf Of Macho, Michael via Powernet Sent: Friday, April 26, 2019 5:58 AM To: powernet@hpspowernet.org Cc:

[Powernet] Diving Remote Monitoring

2019-08-23 Thread Bradley A Krupp via Powernet
Fermi is going to be doing a significant amount of work inside our Torus in our upcoming Spring 2020 outage. In the past we have used the Mirion IMUX and associated hardware to remotely monitor divers radiation exposure. This generally works quite well but our equipment is getting dated and

[Powernet] 5XLB

2019-12-09 Thread Bradley A Krupp via Powernet
Fermi is upgrading our older 5XLB alpha/Beta counters to use the Apex alpha/Beta Software. We were wondering if anyone had any feedback on any things to watch out for on any upgrade they may have done and if anyone would be willing to share any procedure they developed. Thanks in advance for

[Powernet] SRD Chirp

2020-01-27 Thread Bradley A Krupp via Powernet
I know this question has been asked before but Fermi is wondering who among our peers are using the SRD Chirp function for every 1 millirem or some other frequency. If so, why. If not, why not. Thanks in advance for your assistance. Brad Krupp ___

Re: [Powernet] Question on release of fire extinguishers from RCA

2020-01-27 Thread Bradley A Krupp via Powernet
Contact PTI From: Powernet On Behalf Of Stoutenburg, Stephen via Powernet Sent: Monday, January 27, 2020 8:58 AM To: powernet@hpspowernet.org Cc: Stoutenburg, Stephen Subject: [EXTERNAL] Re: [Powernet] Question on release of fire extinguishers from RCA The activity for each extinguisher is

Re: [Powernet] Use of DMC3000 with Diving

2020-01-13 Thread Bradley A Krupp via Powernet
Fermi is planning on it and has purchased all the equipment for our torus recoat project. Decided to go that way after feedback from Brown’s Ferry, Hatch and a couple others. We’ll see how that works out. They all liked it better than the imux. Get Outlook for iOS