Re: [ql-users] OPD Expired!

2007-04-05 Thread Norman
[EMAIL PROTECTED] wrote: I'm just a simple country lad but could I point out that the water in your radiators is most definitly NOT plastic The last time I drained down the system, it looked like plastic, I can assure you of that. Very nasty ! I suspect it had been in there from day one

Re: [ql-users] OPD Expired!

2007-04-04 Thread Norman
[EMAIL PROTECTED] wrote: Morning all, SNIP If, and only if a pin is bent, first ground yourself on a radiator then take a pair of fine pliers or tweezers (available from maplin) = if I might point out, my radiators (10 year old 'modern' house in th UK) have plastic pipes and are not

Re: [ql-users] OPD Expired!

2007-04-04 Thread John Gilpin
- Original Message - From: Billy [EMAIL PROTECTED] To: [EMAIL PROTECTED] Sent: Wednesday, April 04, 2007 1:32 PM Subject: Re: [ql-users] OPD Expired! [EMAIL PROTECTED] wrote: [EMAIL PROTECTED] wrote: Morning all, SNIP If, and only if a pin is bent, first ground yourself

Re: [ql-users] OPD Expired!

2007-04-03 Thread dan volvo
Richard Kilpatrick [EMAIL PROTECTED] wrote: My recently acquired BT Merlin Tonto just died! It's been on for a couple of days demonstrating the auto-answer function; the monitor has been switched off. However, earlier today the phone line went off the hook in an odd way, and the OPD appears

Re: [ql-users] OPD Expired!

2007-04-03 Thread Richard Kilpatrick
On 3 Apr 2007, at 12:40, dan volvo wrote: ii) The sound of the modem 'clicking' and the led lights flashing. If the relay in the modem clicks and the lights flash, you're in business. I think I have a power problem, in that I get the Modem chattering with the LEDs for the line

Re: [ql-users] OPD Expired!

2007-04-03 Thread Richard Kilpatrick
On 3 Apr 2007, at 17:06, Richard Kilpatrick wrote: Okay, can't get anything useful from the mono monitor without more research, but I'm not getting any 5v/12v - I think it needs connections to be made for these to work. But I am now 100% sure that modifying an ICL Medium-Res monitor to

Re: [ql-users] OPD Expired!

2007-04-03 Thread Richard Kilpatrick
On 3 Apr 2007, at 17:55, Richard Kilpatrick wrote: Just another quick update sort of thing :D Schematics of the OPD mono monitor and PSU would be really handy for testing purposes, as I just remembered that I have an Astec Switch- mode PSU from something which has +5v, +12v, -5v, -12v

Re: [ql-users] OPD Expired!

2007-04-02 Thread hitchies
Re: ...Richard, somewhat upset as he's only had the OPD a week :( Commiserations Richard. It's just not fair! Hope it can be fixed. :) Best wishes, John in Wales ___ QL-Users Mailing List http://www.q-v-d.demon.co.uk/smsqe.htm