Pat Redgate
Ameco Solar
In a message dated 12/7/2011 4:28:51 P.M. Pacific Standard Time,
joel.david...@sbcglobal.net writes:
Wrenches,
The California Solar Initiative requires performance monitoring and
We have had two 210's go dark.
With SunPower 225.
We keep one spare 210 in stock (have not had any 190's go yet).
In a message dated 11/3/2011 2:27:30 P.M. Pacific Daylight Time,
ma...@pvthawaii.com writes:
For the first time, several weeks ago, after 40-50 Enphase installs, we’ve
come
Marco:
i would really appreciate it - my photon subscription has rsopped even
tho I am paid up.
Patrick A. Redgate
Ameco Solar, Inc.
7623 Somerset Blvd
Paramount, CA 90723
888-595-9570
_www.solarexpert.com_ (http://www.solarexpert.com)
_www.amecosolar.com_ (http://www.amecosolar.com)
William:
Many non-net-metered folk I know claim that their bills and consumption
have increased dramatically after the arrival of their Smart Meter and have
asked me for advice. For the most part I beg offI'm not really in the
business of testing Smart Meters. The weather has been so
Peter:
In my experience and understanding of the relative electro-negativity or
electrode potential of these two metals, there is not an issue for the copper
to erode to the point of ground failure - the aluminum goes first. In a
marine environment, especially salt water areas, all metals
We recently completed a 130 kW system using Kee Klamps. After contacting
many distributors all over the country we found the best pricing on
quantities and several hard to find 3 Kee Klamp fittings from April Herrera
at
Davis Bacon Material Handling, L.A.,CA 323-227-1921, right around our
Try _www.sunearthinc.com_ (http://www.sunearthinc.com) - a unit called
Copperheart.
Pat Redgate
Ameco Solar
In a message dated 9/24/2010 6:44:23 A.M. Pacific Daylight Time,
hol...@sbcglobal.net writes:
Looking for an equivalent to Thermal Conversion Technology's PT40 SDHW
collector -
Wrenches:
When you have 7 minutes, check out this video on 'fall restraint' -
you may get dizzy (as I did) and
you may wonder, as I did,
HTF they built it in the first place:
_http://video.yahoo.com/network/101149635?v=8244494l=5144241_
Howdy Wrenches:
I don't try to stir things up, but I was just wondering last night as I
fell asleep reading the latest issue of HomePower magazine (# 139), if anybody
else caught a chill when they read this in the Code Corner (highlighted in
a box):
Both microinverters and microinverters
Matt:
Well, thankyou for showing me the dance steps but don't think I'll
stop worrying about this one. I doubt I'll ever bring a skillsaw into
Planning and Building, which is where the dance begins and usually ends.
Besides,
I went cordless a looong time ago and all I ever carry
Bill:
You will need to install MPPT trackers from TIGO and SOLAR MAGIC on all of
your modules, and not just the string in question... as far as I have been
told. I have asked both outfits the same question - and was interested in
SunMizer for this very reason.
But SunMizer seems to be
Joel:
The PV system in Long Beach was built within a stone's throw of a twin
smoke stack for a big furnace devoted to a Trash to Energy project. It
burns garbage to produce energy and LA has plenty of trash. Combine that
with all of the diesel soot being generated by ocean long
Has anybody had any experience with TIGO yet?
I placed an order with DC Power months ago (February) and am still
waiting... would just give up but the product seems so promising and
module/monitoring is one clear benefit.
Pat Redgate
Ameco Solar
In a message dated 6/7/2010 4:21:56 P.M.
Marco:
At what point (kW or cost) does a weather station with online monitoring
make sense?
What (or who ) defines normal weather?
Defining expectations for the large ( 1M) installations must be
particularly vexing - what constitutes normal or expected downtime due to
mechanical
failure
Allan:
Things may have changed since we used them (or rather, vice versa). This
outfit is certainly ramping up their advertising media dollars.
My advice would be
1) Make sure you do not mind having to cancel the credit card you give them
(you may want to terminate service later);
2)
@lists.re-wrenches.org
Sent: Tue, April 20, 2010 12:01:59 PM
Subject: Re: [RE-wrenches] prof liabilty insurance
SEIA has on offician insurance broker:
David Brearley, Senior Technical Editor
SolarPro magazine
NABCEP Certified PV Installer ™
david.brear...@solarprofessional.com
Direct
Good Luck.
pat
In a message dated 4/2/2010 6:09:34 P.M. Pacific Daylight Time,
joel.david...@sbcglobal.net writes:
Wrenches,
I need 5 Astropower (or GE) APX-140 or equivalent 36-cell modules to
replace
customer's broken modules. Please contact me off-list. Thanks in advance.
Best
Bill:
Are you a member of CalSeia?
WE have been very (VERY) busy ... starting from last September. and our
staff has limited resources. For example, today, due to collaborative
efforts, AB 510 is being signed! This is doubling the current 2.5% cap on
net metering - an essential
Get the State AG office to splain it to them (lucy).
Pat Redgate
Ameco Solar, Inc.
In a message dated 2/25/2010 11:29:58 A.M. Pacific Standard Time,
ch...@solarwindworks.com writes:
Cal Seia has helped me in the past with rolling through the local
jurisdiction. Who does their city
I have one very slightly used one... About six years old?
Pat Redgate
In a message dated 2/16/2010 5:28:48 P.M. Pacific Standard Time,
joel.david...@sbcglobal.net writes:
Hello Wrenches,
Who has a SunnyBoy SWR2500U in stock? Please contact me off-list. Thank
you
very much.
Joel
Brian:
It seems to me that this requires the PE to actually commission the
system. A simple wet-stamp on plan submittals is not even indicated by the
paragraph below, but I am certain is required.
Bill, have you had to have a PE provide a commissioning report at the time
of final
This seem ridiculous to me. the idea that an inspector is having you
ground a hot water collector is akin to requiring a pressure relief valve on
a pv module. Or am I missing something here? Ask the manufacturer of the
hot water panel where in the UL listed connection point for the
Mark:
This form is trying to be all things for all residential energy
improvements.
Part one is for non-business Energy Property and Part two is for Energy
Efficiency Property. The tax wonks classify these improvements separately
for their own purposes.
In a message dated 9/9/2009
Here is the draft version of the new 2009 Form 5695 Federal Personal Tax
Credit (Residential):
_http://www.irs.gov/pub/irs-dft/f5695--dft.pdf_
(http://www.irs.gov/pub/irs-dft/f5695--dft.pdf)
Pat Redgate
Ameco Solar
In a message dated 9/8/2009 8:31:41 P.M. Pacific Daylight Time,
Hey, I just found the clearinghouse for all things incredible - this one
looks like it's been around for a while but it's new to me! I am going to
order my cuticle powered alien detector right away!
_www.pesn.com_ (http://www.pesn.com/)
Pat Redgate
Ameco Solar
In a message dated
Michael, Bill:
Our most troublesome areas are in older parts of So Cal (i.e. Pomona) with
higher AC loads. The ancient and undersized transformers just can't
compensate for the sag, especially at the end of the line. Edison WILL
replace
the transformer after the DG customer and all of his
And to my knowledge, there exists no certified, listed or approved 'Quick
Release' mechanism, other than improvised hand-built solutions that are
approved in-situ by the Fire authority having jurisdicktion.
There is a hope of a possibility that a hinged mechanism will be
developed that
Hello again:
This is a brand new 5000 US. EMT on all dc runs. The radio is a
BOSE...and is 27 feet away. The interference is runs 24/7... so it must be AC
related.
I found out today that roam (or freedom) phones do not work at this home.
Since it was built with wire mesh in the walls -
It disappears when the breaker is thrown.
Pat Redgate
In a message dated 7/15/2009 5:11:58 P.M. Pacific Daylight Time,
b...@midnitesolar.com writes:
solar...@aol.com wrote:
This is a brand new 5000 US. EMT on all dc runs. The radio is a
BOSE...and is 27 feet away. The
Hello:
Has anybody got a fix or a way to filter out inverter generated AM (
520-700 kHz MW) noise? I guess it's never been a problem in the past because
our customers must not have been fans of AM radio. Plus, I always approved
of the fact that it wiped out reception for ditto-heads.
This is the one that's got me wondering:
_http://www.youtube.com/watch?v=uMFvzohuVew_
(http://www.youtube.com/watch?v=uMFvzohuVew)
Pat
Ameco Solar
**Dell Days of Deals! June 15-24 - A New Deal Everyday!
Karl et.al.
We are still uncertain as to the date of effectiveness for the various
sweeteners included in the Bill -
this from CalSeia =
...HR 1424 and found this provision that I know you will all want
to know in black-and-white terms:
(f) (2) SOLAR ELECTRIC PROPERTY