[Repeater-Builder] RC 1000 controller code table

2008-12-17 Thread wb8art
Anyone have a copy of an older version of the code user tables? I have chip version rev 4.34, and the RB sites text is rev 4.7.. There are some differences apparently and it would be nice to get the correct tables. Randy

Re: [Repeater-Builder] RC 1000 controller code table

2008-12-17 Thread neal Newman
The Old codes were 3 digits like 100 ,101,102,103 the newer versions had 4 digits 4100,4101,4102 Ect.. try that --- On Wed, 12/17/08, wb8art wb8...@netzero.net wrote: From: wb8art wb8...@netzero.net Subject: [Repeater-Builder] RC 1000 controller code table To: Repeater-Builder

[Repeater-Builder] RC-1000 Controller question

2006-05-11 Thread frostbitnome
Our club has a Maggiore Hi-Pro repeater with an RC-1000 controller. Question: I have the RC-1000 manual, version 4.3 dated July 1, 1995. It escapes me how to access the controller via DTMF to do some changes. I am confused what the A and D control and user codes are. 1. I want to be able to

Re: [Repeater-Builder] RC-1000 Controller question

2006-05-11 Thread John J. Riddell
-Builder] RC-1000 Controller question Our club has a Maggiore Hi-Pro repeater with an RC-1000 controller. Question: I have the RC-1000 manual, version 4.3 dated July 1, 1995. It escapes me how to access the controller via DTMF to do some changes. I am confused what the A and D control

Re: [Repeater-Builder] RC-1000 Controller question

2006-05-11 Thread Jim Brown
Nate, the RC-1000 is programmed by opening the controller for programming input by sending two code sequences. The unlock sequence has a 'D' prefix hard wired and can't be changed as I recall, with two additional characters. A typical sequence would be something like 'D7B' and D7C'. The

Re: [Repeater-Builder] RC-1000 Controller question

2006-05-11 Thread Jim Brown
Access to the AXX and DXX control codes can be enabled or disabled with two control codes; Control Code enable and Control Code disable. When disabled the only control code to function is the Control Code Enable. These codes do NOT affect access to the * and # user codes. The above

Re: [Repeater-Builder] RC-1000 Controller question

2006-05-11 Thread Neal Newman
: Thursday, May 11, 2006 1:13 AM Subject: [Repeater-Builder] RC-1000 Controller question Our club has a Maggiore Hi-Pro repeater with an RC-1000 controller. Question: I have the RC-1000 manual, version 4.3 dated July 1, 1995. It escapes me how to access the controller via DTMF to do some ch

[Repeater-Builder] RC 1000 Controller

2005-03-13 Thread va3vkk
When I program a function for example DTMF Muting enable/disable or Tail beep program Then disable controler codes all is OK but if I loss power it reverts back to previous setting This happens on new changes leading me to think I am missing a step to save them. All others seem OK VA3VKK Kim

Re: [Repeater-Builder] RC 1000 Controller

2005-03-13 Thread albemarle7
The Ron Wright RC1000 is a little tricky. Make sure you have the correct Control Program Select Code List (Table 15.1) for the Revision of your controller. You should use the table that is in the book that came with the controller. They are all different. I have a number of these RC1000

RE: [Repeater-Builder] RC 1000 Controller

2005-03-13 Thread Mike Mullarkey
] www.orlg.org -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Sent: Sunday, March 13, 2005 10:54 AM To: Repeater-Builder@yahoogroups.com Subject: Re: [Repeater-Builder] RC 1000 Controller The Ron Wright RC1000 is a little tricky. Make sure you have the correct Control

RE: [Repeater-Builder] RC 1000 Controller

2005-03-13 Thread Richard
. It is unlikely though, as they are pretty bullet proof. Richard, N7TGB -Original Message- From: va3vkk [mailto:[EMAIL PROTECTED] Sent: Sunday, March 13, 2005 10:28 AM To: Repeater-Builder@yahoogroups.com Subject: [Repeater-Builder] RC 1000 Controller When I program a function

Re: [Repeater-Builder] RC 1000 Controller

2005-03-13 Thread albemarle7
ReRC1000..I experienced same problem you mentioned about it accepts the instruction by giving RR but it really didn't. I call the controller the fortune cookie controller because it lies to me by saying it accepted the code but it really didn't. First off, don't be afraid to do a reset

[Repeater-Builder] RC-1000 Controller

2003-11-16 Thread va3vkk
RC-1000 Controller by Micro Computer Concepts Unable to gain access after I enabled the programing control 1 2 made my adjustments. Disabled program control. The controller acepted the changes. When it came time to disable access I could not get a response. I am out of programing mode for sure.

Re: [Repeater-Builder] RC-1000 Controller

2003-11-16 Thread Steve S. Bosshard \(NU5D\)
PROTECTED] To: Repeater-Builder@yahoogroups.com Sent: Sunday, November 16, 2003 8:26 AM Subject: [Repeater-Builder] RC-1000 Controller | RC-1000 Controller by Micro Computer Concepts | Unable to gain access after I enabled the programing control 1 2 | Your use of Yahoo! Groups is subject

Re: [Repeater-Builder] RC-1000 Controller

2003-11-16 Thread Kim Krueger
Subject: Re: [Repeater-Builder] RC-1000 Controller on programming commands with an D like D14 to enable programming the cwid, do not enter the D. Also commands with #, like #9 to force ID, enter 09 and do not enter #. Had the same challange last Thursday. Once programmed really works well