Title: RE: BSOD with Retrospect 5.1 Server
Thanks Ben and Irena for your answers. It was indeed the ASPI problem, and ASPI install fixed it.
The same server had Netshield on it, which I removed at the same time.
It was also choking halfway through a backup, which I traced (I believe) to
Hello,
We had a number of customers report problems with configurations that
include Intergraph computers. On such configurations, scanning the SCSI bus
from within Retrospect or with other utilities results in a blue screen,
requiring a reboot of the computer. By conducting tests in association
ould be gratefully accepted.
Thanks,
Rob
> --
> From: Ben Eastwood
> Reply To:retro-talk
> Sent: Tuesday, 5 December 2000 3:52 AM
> To: [EMAIL PROTECTED]
> Subject: BSOD with Retrospect 5.1 Server
>
>
>
> I get a reproducable blue screen on
Title: RE: BSOD with Retrospect 5.1 Server
Yes!
I also have a 1600R with RAID 5 and Retrospect 5.15. It also crashes everytime it does a device scan in ineteractive mode. It doesn't crash when it autolaunches (well, usually - I have found some unexpected restarts the next morning, but
I get a reproducable blue screen on a compaq 1600 R with two smart array
controllers (221 and 3200) both controlling RAID 5 arrays. The crash
happens everytime I do the device scan. I think it's related to the RAID
controllers, but I'm not sure. Has anyone seen this behavior before?
Machine is