Re: [Wien] optimization of an orthorhombic cell

2017-10-20 Thread Dr. K. C. Bhamu
Dear Prof. Tomas, Yes, it might be a problem of misplaced of all three scripts. Not its running for scf and each scf cycle is running triply. A new issue what I observed is (before scf starts): *mv: mv: cannot stat 'A*.scf'cannot stat 'A*.scf': No such file or directoryBefore running

Re: [Wien] optimization of an orthorhombic cell

2017-10-20 Thread Tomas Kana
Dear Bhamu, It seems to me from the error messages that you might not place the scripts volumeOrtho and cellShapeOrtho into the case directory. I see nowhere the name of your case in the messages. Or is the name of your directory OrthoOpt? Than you should have inside the files OrthoOpt.struct

Re: [Wien] optimization of an orthorhombic cell

2017-10-18 Thread Dr. K. C. Bhamu
y minimum > along one slice, fix it, then go on with the next slice, etc. … you can > gradually approach the absolute energy minimum. It might take several > iterations through this scheme if your starting cell is far away from the > minimum. Best is to start first with the degree of free

Re: [Wien] optimization of an orthorhombic cell

2017-10-18 Thread Tomas Kana
). Stefaan Předmět: Re: [Wien] optimization of an orthorhombic cell Dear List, Could you please help me to get optimize lattice parameters from the procedure that I followed as mentioned below: The procedure is a four-step task what I am following: The original lattice parameters were: a, b, c

Re: [Wien] optimization of an orthorhombic cell

2017-10-14 Thread Dr. K. C. Bhamu
Namens *Dr. > K. C. Bhamu > *Verzonden:* vrijdag 13 oktober 2017 14:04 > *Aan:* A Mailing list for WIEN2k users <wien@zeus.theochem.tuwien.ac.at> > *Onderwerp:* Re: [Wien] optimization of an orthorhombic cell > > > > Thank you very much for a hint. > > I thought the value

Re: [Wien] optimization of an orthorhombic cell

2017-10-13 Thread Stefaan Cottenier
14:04 Aan: A Mailing list for WIEN2k users <wien@zeus.theochem.tuwien.ac.at> Onderwerp: Re: [Wien] optimization of an orthorhombic cell Thank you very much for a hint. I thought the value obtained from "VARY C/A RATIO with CONSTANT VOLUME and B/A (orthorh lattice)" are well opti

Re: [Wien] optimization of an orthorhombic cell

2017-10-13 Thread Dr. K. C. Bhamu
> Von: Wien [wien-boun...@zeus.theochem.tuwien.ac.at] im Auftrag von Dr. K. > C. Bhamu [kcbham...@gmail.com] > Gesendet: Freitag, 13. Oktober 2017 00:42 > An: A Mailing list for WIEN2k users > Betreff: Re: [Wien] optimization of an orthorhombic cell

Re: [Wien] optimization of an orthorhombic cell

2017-10-12 Thread Fecher, Gerhard
uftrag von Dr. K. C. Bhamu [kcbham...@gmail.com] Gesendet: Freitag, 13. Oktober 2017 00:42 An: A Mailing list for WIEN2k users Betreff: Re: [Wien] optimization of an orthorhombic cell Dear List, Could you please help me to get optimize lattice parameters from the procedure that I followed as

Re: [Wien] optimization of an orthorhombic cell

2017-10-12 Thread Dr. K. C. Bhamu
Dear List, Could you please help me to get optimize lattice parameters from the procedure that I followed as mentioned below: The procedure is a four-step task what I am following: The original lattice parameters were: a, b, c=16.763005, 24.803600, 16.320431 >> vol 6785.64777697697 bohr^3.

Re: [Wien] optimization of an orthorhombic cell

2017-10-12 Thread Laurence Marks
13 years old! Peter, perhaps that pdf should be removed, or at least updated. --- Professor Laurence Marks "Research is to see what everybody else has seen, and to think what nobody else has thought", Albert Szent-Gyorgi http://www.numis.northwestern.edu Corrosion in 4D

Re: [Wien] optimization of an orthorhombic cell

2017-10-12 Thread Laurence Marks
I did not write notes on cell optimizations, just MSR1a. Swamped. --- Professor Laurence Marks "Research is to see what everybody else has seen, and to think what nobody else has thought", Albert Szent-Gyorgi http://www.numis.northwestern.edu Corrosion in 4D http://MURI4D.numis.northwestern.edu

[Wien] optimization of an orthorhombic cell

2017-10-12 Thread Dr. K. C. Bhamu
Dear Prof. Marks, I read your optimization notes for orthorhombic cell and tried to optimize an orthorhombic cell but I could not obtain an optimization plot. So I am following the standard procedure as below taken from your suggestion in the mailing list https://www.mail-archive.com/