[WISPA] CPE...Cat5...grounding

2006-03-26 Thread Brian Rohrbacher
Ok, I am searching for cat5 with ground wire attached. How well do you think a coax would work to ground the CPE? http://www.computercablestore.com/detail.aspx?ID=2098 It's not like I am trying to protect it from lightning (good luck) I just want somewhere for the static to go. I could

RE: [WISPA] CPE...Cat5...grounding

2006-03-26 Thread Mike Bushard, Jr
I have been looking for Shielded Cat5e with a ground wire attached for a long time also. I was thinking of calling belden and asking them what it would take to make it. Mike Bushard, Jr Wisper Wireless Solutions, LLC -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On

RE: [WISPA] CPE...Cat5...grounding

2006-03-26 Thread Rick Harnish
Can't you just use shielded Cat5E cable to do this. We use it on all tower installs but not for CPE's. Rick Harnish President OnlyInternet Broadband Wireless, Inc. 260-827-2482 Office 260-307-4000 Cell www.oibw.net [EMAIL PROTECTED] -Original Message- From: [EMAIL PROTECTED]

Re: [WISPA] CPE...Cat5...grounding

2006-03-26 Thread KyWiFi LLC
What do you ground the shield to? We are needing to ground the mounting arm. Plus, I would think that it would be hard to attach the shield to a ground rod plus this would require that the Cat5 be cut outside which is something we are wanting to prevent. If we had a Cat5 with an attached ground

Re: [WISPA] Wire Line Local Service Question

2006-03-26 Thread Rick Smith
I think that because Sprint owns the wire plant in your case, they have to charge it I thought the cases where they could drop those other charges were where your dsl provider's just providing dsl on a copper loop without phone service whatsoever... [EMAIL PROTECTED] wrote: I keep hearing

Re: [WISPA] CPE...Cat5...grounding

2006-03-26 Thread Blair Davis
Well, I use a outdoor, shielded, flooded, cat5 with drain wire. About $80 or so per 1000ft. The drain wire is awg 24 or so, but, it serves the purpose of bleeding off the static charge and protecting the ethernet port on the radio and the computer/router. I have had no ethernet port damage

Re: [WISPA] CPE...Cat5...grounding

2006-03-26 Thread Blair Davis
Even a shielded, flooded cat5 with messenger would work, but I have been searching for that for years with no luck. When I worked for a cable company, (many years ago), we had an RG-6 cable with a copper plated steel messenger line. It worked for overhead work as well as grounding.