All,
I've seen this situation now several times, and wonder if someone on
the list has an explaination for it. Last week we took down one of
our APs (802.11b) for several hours to replace it with a new one. We
ran into some issues and had to fall back to using the original
system. We brought
rabbtux rabbtux wrote:
Of the 25 subs, 4 or 5 CPEs did not re-associate with the AP. All
was cleared up when customers called were instructed to recycle
power to outdoor CPEs. This situation happened to 3 different types
of CPEs that we have in the field for this AP.
I don't think that's
What are the brands of the client units? They might very well have
the same gear inside which could account for the similar behaviour.
Lonnie
On 11/8/06, rabbtux rabbtux [EMAIL PROTECTED] wrote:
All,
I've seen this situation now several times, and wonder if someone on
the list has an
Clients were based on both Senao radio CPEs and Zinwell CPEs
On 11/8/06, Lonnie Nunweiler [EMAIL PROTECTED] wrote:
What are the brands of the client units? They might very well have
the same gear inside which could account for the similar behaviour.
Lonnie
On 11/8/06, rabbtux rabbtux [EMAIL