Re: [WISPA] Any Status Updates?

2006-12-02 Thread Travis Johnson
John, The real issue is that Mikrotik is ignoring the problem. I have personally emailed John Tully @ MT four or five times with no response. I posted a message on their support forum back in July or August and it was deleted. One of my partners posted a message on their support forum (with

RE: [WISPA] Any Status Updates?

2006-12-02 Thread Rick Harnish
John, The last I heard, it was an issue caused by running the boards on 48 vDC. I don't think it is a problem if you are running them on lower voltages. I have a partner WISP that was causing some problems on a fire department frequency. It caused a clicking noise in their radio

RE: [WISPA] Any Status Updates?

2006-12-02 Thread Mike Delp
John, we had an instance of the voltage regulator on the 532 causing interference in the public safety band (154 MHz). We were able to change it to 12V and the problem went away. 48V had a problem, and 12V fixed our problem. I have not heard anything official from MT on this issue. The