Re: [zones-discuss] preferred way to image-update zones

2009-12-05 Thread Thomas Tornblom
Jordan Vaughan skrev: On 12/ 4/09 02:28 PM, Anil wrote: Once a the global zone is upgraded (and rebooted with the new BE), what is the best way to update the zones? It seems like all I would need to do is: pkg -R zone path/root image-update reboot zone This seems like a hack, how would post

[zones-discuss] capped-memory on a zone

2009-12-05 Thread andrew
I am working on zones for my honours project at uni. I created a zone with capped-memory and now I want to remove the caps. I deleted the capped-memory entries from the zone configuration using zonecfg. I then rebooted the zone as it didn't seem to take effect, but upon rebooting vmstat is

Re: [zones-discuss] capped-memory on a zone

2009-12-05 Thread andrew
I am working on zones for my honours project at uni. I created a zone with capped-memory and now I want to remove the caps. I deleted the capped-memory entries from the zone configuration using zonecfg. I then rebooted the zone as it didn't seem to take effect, but upon rebooting vmstat is

[zones-discuss] problem with zone networking

2009-12-05 Thread andrew
I'm not sure what the problem is here. I have created a vnic over an existing physical nic as follows: dladm create-vnic -l e1000g0 e1000g1 I then use e1000g1 (the VNIC) as the interface for an exclusive-IP zone. Problem 1: upon rebooting the host e1000g1 is only half there in that it doesn't

Re: [zones-discuss] problem with zone networking

2009-12-05 Thread andrew
I'm not sure what the problem is here. I have created a vnic over an existing physical nic as follows: dladm create-vnic -l e1000g0 e1000g1 I then use e1000g1 (the VNIC) as the interface for an exclusive-IP zone. Problem 1: upon rebooting the host e1000g1 is only half there in that it

Re: [zones-discuss] problem with zone networking

2009-12-05 Thread andrew
I'm not sure what the problem is here. I have created a vnic over an existing physical nic as follows: dladm create-vnic -l e1000g0 e1000g1 I then use e1000g1 (the VNIC) as the interface for an exclusive-IP zone. Problem 1: upon rebooting the host e1000g1 is only half

Re: [zones-discuss] preferred way to image-update zones

2009-12-05 Thread Anil
It seems to be -U, looking at the source at least: http://cvs.opensolaris.org/source/xref/onnv/onnv-gate/usr/src/cmd/zoneadm/zoneadm.c#attach_func -- This message posted from opensolaris.org ___ zones-discuss mailing list zones-discuss@opensolaris.org