Update: I tried selecting a filter and right after that selecting FixF without reploting and that does seem to work and fix a filter. The problem is that I can’t seem to do that with a user defined filter... Is there a workaround?
Regards, Emanuel Antunes Integrated Master Degree (MSc) in Physics Engineering M.Sc. Thesis - Seismology Laboratory Instituto Superior Técnico (IST) - Lisbon Technical University (UTL) On 2012/10/10, at 09:11, [email protected] wrote: > you can also fix the filter from mulplt see fixf in the menu. Otherwise, > mulplt always returns to the raw data when you replot. > > Lars > > Quoting Branden Christensen <[email protected]>: > >> Emanuel: >> >> >> One can fix a specified filter during the entire mulplt session. >> >> e.g., >> >> osop@queretaro:/opt/seismo/WAV$ mulplt >> Filename, number, filenr.lis (all) >> Continuous SEISAN data base: cont >> Large SEED volume: conts >> Bud archive: bud >> SEISCOMP archive: scp >> >> 1 >> Read headers from files: >> 2011-11-05-2149-08S.MAN___038 >> >> >> Plot options: Interactive picking Return >> Multi trace plot on screen, def (0) >> Multi trace plot on screen (1) >> Multi trace plot on screen+laser(2) >> Multi trace plot on laser (3) >> Continuoues on screen (4) >> Continuoues on screen + laser (5) >> Continuoues on laser (6) >> Stop (q) >> >> Low and high cut for filter, return for no filter >> 10 15 >> >> This will set a bandpass filter from 10 to 15 Hz for the entire mulplt >> session. >> >> >> Atte. >> >> >> *Branden C. Christensen* >> Director, OSOP >> *[email protected]* >> www.osop.com.pa >> Volcan, Panama >> >> >> >> >> >> On Tue, Oct 9, 2012 at 4:53 PM, Emanuel Antunes >> <[email protected]>wrote: >> >>> Dear All, >>> >>> >>> I have searched for a solution to this problem but was unsuccessful in >>> doing so. You have been most helpful in helping me solve my previous >>> problem, so once again I resort to your collective expertise. >>> I would like to know if it is possible to set up a default filter so that >>> wavefiles are always opened with that filter when one uses mulplt or option >>> "p"/"po" in eev. In order to toggle between single channel or multichannel >>> modes. Alternatively, can one fix a specified filter during the entire >>> mulplt session? >>> Thanks in advance. >>> >>> Best regards, >>> >>> >>> *Emanuel Antunes* >>> >>> Integrated Master Degree (MSc) in Physics Engineering >>> M.Sc. Thesis - Seismology Laboratory >>> Instituto Superior Técnico (IST) - Lisbon Technical University (UTL) >>> >>> >>> >>> >>> >>> _______________________________________________ >>> seisan mailing list >>> [email protected] >>> http://mailman.uib.no/listinfo/seisan >>> >>> >> > > > _______________________________________________ > seisan mailing list > [email protected] > http://mailman.uib.no/listinfo/seisan
_______________________________________________ seisan mailing list [email protected] http://mailman.uib.no/listinfo/seisan