Hi, Bert,

Thanks for your suggestion.
I agree that SR_DF_META packet is a proper way to send it.

My device like usbee dx is not a real usbee dx. it is made by myself
from PCB to plastic case. and probes are cheap Chinese ones like other
clones.

But it works well on Windows without any problem, especially without
any delay between digital sample and analog sample of the same signal.
So I think it works like real USBee DX.

But I heard that some clone has some timing issues from a forum. I
think it's due to different parasitic capacitance of digital and
analog lines. I heard they used different parts in analog and digital
lines, something like OP-AMP and voltage protection diodes. And even
different PCB artwork can make it.

I don't have those clones so I'm not sure. but I think analog signal
delay value could be a user-defined value. So like other configuration
key, this might use the same way.

If someone has a clone, please check and let me know it.

On defining configuration key, I think already-defined
SR_CONF_TRIGGER_SLOPE key is proper for trigger slope of oscilloscope,
This value is bound to uint64_t type and shown as integer value on
pv's dialog box. I think this value could be changed to more readable
value(rising or falling) for usual users. Is there any reason to be
shown as integer value?

Best regards,
Jong-Jin.

------------------------------------------------------------------------------
Rapidly troubleshoot problems before they affect your business. Most IT 
organizations don't have a clear picture of how application performance 
affects their revenue. With AppDynamics, you get 100% visibility into your 
Java,.NET, & PHP application. Start your 15-day FREE TRIAL of AppDynamics Pro!
http://pubads.g.doubleclick.net/gampad/clk?id=84349831&iu=/4140/ostg.clktrk
_______________________________________________
sigrok-devel mailing list
sigrok-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/sigrok-devel

Reply via email to