On Fri, 20 Dec 2013 15:29:59 +0900, Jong-Jin Kim
<jongjin.kim....@gmail.com> wrote:

> On defining configuration key, I think already-defined
> SR_CONF_TRIGGER_SLOPE key is proper for trigger slope of oscilloscope,
> This value is bound to uint64_t type and shown as integer value on
> pv's dialog box. I think this value could be changed to more readable
> value(rising or falling) for usual users. Is there any reason to be
> shown as integer value?

That key actually refers to the trigger edge: rising or falling.


-- 