On Sun, Oct 16, 2016 at 06:25:20PM +0200, Gerhard Sittig wrote:
> The driver internally implements the "limit samples" feature by means of
> the "limit sample period" approach.  Determination of the corresponding
> period of time for captures depends on the sample rate as well as the
> maximum sample count, and thus needs to be re-done when either setting
> changes.
> Introduce a "limit_samples" variable so that the value is available when
> needed later.  As a byproduct the parameter can be retrieved now (get).
> Add comments to the sigma_set_samplerate() routine's sections, since
> quite a bit is happening there, and interacts with other locations.
> Signed-off-by: Gerhard Sittig <gerhard.sit...@gmx.net>

Merged, thanks!

http://hermann-uwe.de | http://randomprojects.org | http://sigrok.org