Am Samstag, den 29.07.2017, 18:27 +0200 schrieb Gerhard Sittig: > Can you please check the patch that I whipped up? Have tested with > 5MSa at 1MSa/s with full (self-stopping) and short (interactively > stopped) acquisitions, several times. Works for me. > > http://repo.or.cz/libsigrok/gsi.git/shortlog/refs/heads/asix-sigma-user-stop > > git://repo.or.cz/libsigrok/gsi.git asix-sigma-user-stop > > Can't tell whether other non-streaming devices suffer from > similar issues. >
Hi! I just tested your changes, and it works like a charm now :-) I tried at several sampling rates (up to 50MHz) - everything ok - except that there is no UI feedback when fetching large data from the device (setting 500MSamples at 50MHz and pressing stop around 5 seconds ... UI freezes for some seconds) but I guess this is a pulseview related thing. Anyway, now I can actually do some work with the asix sigma device :-D Thank you very much for your help! Best regards, Michael Kaplan ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ sigrok-devel mailing list sigrok-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sigrok-devel