Am Samstag, den 29.07.2017, 18:27 +0200 schrieb Gerhard Sittig:
> 
Can you please check the patch that I whipped up?  Have tested with
> 5MSa at 1MSa/s with full (self-stopping) and short (interactively
> stopped) acquisitions, several times.  Works for me.
> 
>   http://repo.or.cz/libsigrok/gsi.git/shortlog/refs/heads/asix-sigma-user-stop
> 
>   git://repo.or.cz/libsigrok/gsi.git asix-sigma-user-stop
> 
> Can't tell whether other non-streaming devices suffer from
> similar issues.
> 


Hi!

I just tested your changes, and it works like a charm now :-)

I tried at several sampling rates (up to 50MHz) - everything ok - except that
there is no UI feedback when fetching large data from the device (setting
500MSamples at 50MHz and pressing stop around 5 seconds ... UI freezes for some
seconds) but I guess this is a pulseview related thing.

Anyway, now I can actually do some work with the asix sigma device :-D

Thank you very much for your help!


Best regards,
Michael Kaplan
------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
sigrok-devel mailing list
sigrok-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/sigrok-devel

Reply via email to