On Mon, Jul 31, 2017 at 09:43 +0200, KAPLAN Michael / EVVA Wien wrote: > > Hi! > > I just tested your changes, and it works like a charm now :-)
Thank you for testing! > I tried at several sampling rates (up to 50MHz) - everything ok > - except that there is no UI feedback when fetching large data > from the device (setting 500MSamples at 50MHz and pressing stop > around 5 seconds ... UI freezes for some seconds) but I guess > this is a pulseview related thing. It appears to be the result of the specific combination of a non-streaming device with slow(?) sample data downloads and/or huge amounts of sample data to retrieve, which results in an extended period of time between pressing the button and starting to draw traces, where the user cannot perceive progress or feedback from the UI. IOW it may be non-trivial to reproduce. Have filed https://sigrok.org/bugzilla/show_bug.cgi?id=1003 for this issue. Can you please check and maybe add information in case I missed something? virtually yours Gerhard Sittig -- If you don't understand or are scared by any of the above ask your parents or an adult to help you. ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ sigrok-devel mailing list sigrok-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sigrok-devel