Dear cs'ers, I recently had the opportunity to play with a spectrophotometer.Using the instruction book procedures gave the following readings:
I took readings at wavelengths for blue(470nm),green(555nm),yellow(585nm),orange(610nm) and red(650nm).The results indicated a figure for Absorption(A) and Transmission(T) %. Blue;A=0.143 T=71.8 ,Green;A=0.136 T=73.2 Yellow;A=0.118 T=75.9 Orange;A=0.115 T=76.8 Red;A=0.093 T=80.7 My question for those familiar with this apparatus is; What particle size could be ascertained from these results? My cs production method uses 27v and halts at 8mA using spiral shaped electrodes spaced 25mm apart.Results are a clear solution (no colour) but a slight tyndall effect observable via high power(1w) leds Thank you for taking time to reply. pete ********************************************************************** This message is intended for the addressee named and may contain privileged information or confidential information or both. If you are not the intended recipient please delete it and notify the sender. **********************************************************************