On 01/12/2010 09:03 AM, Uttam Sarkar wrote:

> I think if the "Privacy: none" present then one can use either use
> display caller from "From" header or it can use User Part from RPID
> header.

Any idea why the Sonus implementation would ignore the presence of RPID 
and insist on using the From if 'Privacy: none'?  It seems to me that, 
as you say, 'Privacy: none' doesn't change anything and so it should not 
behave any differently than if 'Privacy' were altogether absent.

If 'Privacy' is absent, the Sonus does use the user part of the RPID. 
But if it's set to 'none', it is ignored.


-- 