On Fri, 2009-02-27 at 16:08 -0800, Chris Harris (InfoStructure Systems)
wrote:
> Any one on this Forum.  I am new to SipX and trying to help a customer
> connect their SipX equipment to our node.  I was just wondering if
> anyone has any ideas from my prior message.  I am sorry to be a bug
> but this customer would really like to use SipX to connect to our voip
> node.

If you're referring to the message quoted below, it never came through
(if the message was over 60K the list won't accept it).

> Chris Harris (InfoStructure Systems) wrote: 
> > Scott,
> > 
> > I have attached the sip trace file.  The test call went as follows.
> > >From a PSTN call the voip DID -> connected to our voip node
> > (69.9.148.24) -> trys to connect to sipX(69.9.130.21) -> commicates
> > back to voip node (69.9.148.24) with 407 error.

You didn't say which version of sipXecs your debugging - it matters a
lot because the current stable and development versions send that
response for some different reasons.  (If we'd seen the trace, we'd have
been able tell from version info in the messages...).