--- On Mon, 4/12/10, Scott Lawrence <[email protected]> wrote:
> 
> >  
> > IMO we shouldn't enforce any max length on these
> fields, but only
> > validate it's a valid value (that's it, an int value).
> 
> 
> Not that it's an int... that it's a sequence of dial string
> characters.
> 
> '[0-9*#]+'

Checked the code and right now we are handling extensions as integers - (first, 
last and next extensions are defined as integers in extension_pool table). 
Since is too late to make such a change in this release I propose to keep 
extensions as integers and to track this change in a separate JIRA issue 
(unless we agree that this one is something critical and we really have to push 
it in the current release).

Please comment.

George  


      

_______________________________________________