On Wed, 2009-05-13 at 12:30 -0400, M. Ranganathan wrote:

> On Wed, May 13, 2009 at 12:13 PM, James R <[email protected]> wrote:
> Take a look at Gateway.java. There is a switch for this behavior.
> Enable that switch (make the boolean true). Recompile the source code,
> replace sipxbridge.jar in your install and see if it works for you.
> Let us know how it goes.

This will _not_ make any difference for an ACD call; the REFER never
gets back to sipXbridge - the ACD is itself a B2BUA, and will deal with
the REFER locally.