Content-Type: text/plain;
  charset="utf-8"
Content-Transfer-Encoding: 8bit
Organization: SipXecs Forum
X-FUDforum: 08063afcdd00a6e76393c5b9527381e8 <43551>
Message-ID: <[email protected]>



Hi there,

I have searched for solution of my problem but unfortunately
I didn't find it yet.

So, the problem as usually in Nat configuration. I have
followed different instructions on how to setup sipXecs
behind Nat but unfortunately still didn't achieved result.
So, step by step.

My sipXecs is installed on separate PC inside local network
from CentOS  live cd, downloaded from sipX site. I have
tried version 4.0.4 and 4.1.6 of sipX. This PC has local IP
192.168.0.66 and has access to internet via gateway(router)
192.168.0.100. With sipXconfig I have setup this IP and
domain is yukon.cv.ua (on a router I have properly
configured all redirections to this PC).

In a router I have redirected ports TCP/UDP 5060, and
31112-31116 UDP to 192.168.0.66 so it is accesible from
outside.

In sipXecs web admin I have turned on in Internet Calling->
Nat traversal both checkboxes (Enable NAT Traversal, Server
behind NAT), have limited Intranet subnet to 192.168.0.0/24
(Internet Calling -> Internet Calling).
In Servers -> <ServerName> -> NAT I have specified public
static IP address (82.207.124.XXX) and specified Start RTP
port - End RTP port to 31112 - 31116. Public port remains
default 5060.
In Services tab all services are running.

I am able to make and receive calls from any local machine,
but I'm not able to hear anything from machines which
connects to this pbx from Internet. That Internet PC are
able to register in pbx  and even make calls, but
unfortunately no sound is passed to them.

I have used wireshark to see what happens in remote(internet
PC) and I have noticed that in SDP there is no correct IP
and port specified.
Owner/Creator, Session Id (o): FreeSWITCH 344835710026207136
2191952713175813000 IN IP4 192.168.0.66
Media Description, name and address (m): audio 12688 RTP/AVP
0 101
There are at least two problems -
1. sipXproxy doesn't substitute local IP to public
2. sipXproxy doesn't set correct port, it remains same as in
freeswitch server configuration.

I don't know if sipXproxy is responsible for this
substitutions, probably it is responsibilities of sipXrelay.
I have tried everything in configuration, but this one I
cannot resolve.
I have tried even this
http://sipx-wiki.calivia.com/index.php/Configuring_remote_workers_cheatsheet.
Still no luck.

I would appreciate any help.

If more info is necessary I can provide it.

_______________________________________________
sipx-users mailing list [email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to