if you turn on loggin from a pc connected to it, does the logging from
the AC gateway tell you anything (stupid question, because you are
remote).

Did you ever have this working at all?

How did you setup the gateway (manually or let sipx generate the config file)?

On Wed, Sep 1, 2010 at 3:36 PM, Kyle Haefner <[email protected]> wrote:
> No it doesn't seem to complete, the remote office phone never rings.
>
> I see the REFER come into the gateway from sipx, the gateway follows with a
> NOTIFY back to sipx, then a 202 Accepted.  I feel like I should see an
> INVITE from the gateway in there after the REFER, but I never do.
>
>
> Tony,
>
> For small office FXO what would you recommend?
>
> Thanks!
>
> Kyle
>
>
> On 09/01/2010 01:23 PM, Tony Graziano wrote:
>>
>> I don't use AC gateways if I can help it. ;>)
>>
>> You never mentioned if it successfully connects the call. It's an
>> audio or MOH issue for sure. Have you done anything differently in
>> this system regarding MOH?
>>
>>
>> On Wed, Sep 1, 2010 at 2:45 PM, Kyle Haefner<[email protected]>
>>  wrote:
>>>
>>> Hi All,
>>>
>>> I have spXecs 4.2.1 and an Audiocodes MP114 FXO device (version 5.8)
>>> for a remote office.  When I call into the FXO device from the PSTN to
>>> an auto-attendant, I can push a digit and I hear "Please hold while I
>>> transfer your call" then dead air and no phones ring in the remote
>>> office.  If I dial in from another internal  extension (ie a polycom)
>>> to the auto-attendant then it transfers as expected.  Anybody see this
>>> before?
>>>
>>> Kyle
>>> _______________________________________________
>>> sipx-users mailing list
>>> [email protected]
>>> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>>>
>>
>>
>>
>
>



-- 
======================
Tony Graziano, Manager
Telephone: 434.984.8430
sip: [email protected]
Fax: 434.984.8431

Email: [email protected]

LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
sip: [email protected]
Fax: 434.984.8427

Helpdesk Contract Customers:
http://www.myitdepartment.net/gethelp/