I updated to the latest version of sipXecs last night.  This morning – our 911 
department said they could no longer transfer calls.  Could be non-related, but 
thought I’d double check for similar issues.

Here is the call setup/scenario:

Inbound calls are from Verizon PRI into Patton 5960 – calls go to sipXecs – the 
admin lines for 911 are on an audiocodes mp 118 fxs.  Once the call is answered 
and they attempt to transfer the call to our legacy NEC box – the call just 
rings back on the analog sipXecs line.  They did say that if they immediately 
hang up and don’t let it ring, the call will transfer successfully.

Any thoughts?

I of course don’t have any logs to offer yet – but will get them when I get a 
few minutes

Thanks,

________________________________
This message and any files transmitted with it are intended only for the 
individual(s) or entity named. If you are not the intended individual(s) or 
entity named you are hereby notified that any disclosure, copying, distribution 
or reliance upon its contents is strictly prohibited. If you have received this 
in error, please notify the sender, delete the original, and destroy all 
copies. Email transmissions cannot be guaranteed to be secure or error-free as 
information could be intercepted, corrupted, lost, destroyed, arrive late or 
incomplete, or contain viruses. Garrett County Government therefore does not 
accept any liability for any errors or omissions in the contents of this 
message, which arise as a result of email transmission.


Garrett County Government,
203 South Fourth Street, Courthouse, Oakland, Maryland 21550 
www.garrettcounty.org
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to