Looks like you may need to register with them to create a login. There is 
support maintenance that is needed on the device to download software. There 
may be other options however I do not know of any other then the manufacturer.
 
Rob
 
From: [email protected] 
[mailto:[email protected]] On Behalf Of Robert Schroeder
Sent: Tuesday, March 20, 2012 5:07 PM
To: [email protected]
Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated
 
Do you have an account with AudioCodes. You should be able to download from 
them.
 
Rob
 
From: [email protected] 
[mailto:[email protected]] On Behalf Of Jorge E. Fernandez
Sent: Tuesday, March 20, 2012 5:00 PM
To: Discussion list for users of sipXecs software
Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated
 
Where can I get version 6.0? 
 
--
Jorge
 
 
 
On Mar 20, 2012, at 4:14 PM, Mark Wood wrote:
 
Version 6.2.xxxxx has given us all kinds of problems. We always downgrade to a 
6.0 version
 
Thanks,
Mark W. Wood
office: (760)202-0224   X2010
Direct: (760)459-1981
<image001.png>
www.redphonetech.com
 
 
 
 
From: Jorge E. Fernandez [mailto:[email protected]] 
Sent: Tuesday, March 20, 2012 12:53 PM
To: Discussion list for users of sipXecs software
Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated
 
Im running an even higher version
 
Version ID: 6.20.A022.003
DSP Type: 0
DSP Software Version: 62008
DSP Software Name: 204IM
Flash Version: 199
 
--
Jorge
 
 
 
On Mar 20, 2012, at 3:49 PM, Robert Schroeder wrote:


Just for information purposes. This is the device information for the 
AudioCodes Mediant 1000 device that we are using with three PRI circuits on 
trunk modules.
 


 
 


  Version ID:   
 6.00A.032.003

  DSP Type:   
 2

  DSP Software Version:   
 60008

  DSP Software Name:   
 624AE3

  Flash Version:   
 208
 
Rob
 
From: [email protected] 
[mailto:[email protected]] On Behalf Of Todd Hodgen
Sent: Tuesday, March 20, 2012 3:43 PM
To: 'Discussion list for users of sipXecs software'
Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated
 
Might try running 5.6 or 5.8 code to see if that helps.   No reason for it, but 
I haven't been running the 6.x code.   Mainly because I haven't seen anyone 
state they are working with no issues on it, and I've seen that on the 5.6 and 
5.8 code.
 
From: [email protected] 
[mailto:[email protected]] On Behalf Of Tony Graziano
Sent: Tuesday, March 20, 2012 12:32 PM
To: Discussion list for users of sipXecs software
Subject: Re: [sipx-users] Audiocodes MP118 487 Request Terminated
 
Do you have an internal dns table setup on the gateway?
I would turn up the logging level on the gateway and review that to see where 
it leads you.
On Mar 20, 2012 3:27 PM, "Jorge E. Fernandez" 
<[email protected]> wrote:
Im experiencing an issue with apparently random calls where they go straight 
busy tone... It only happens on about 50% of calls that go out through the 
gateway. When I trace the calls the gateway returns a "487 Request Terminated" 
after the INVITE and when I go through the syslog from the gateway I find this 
error while its handling the invite
 
(   lgr_stk_ses)(10026     ) !! [ERROR] SIPStackSession::HandleStackSetupEV 
failed because no remote IP
 
The audiocodes is running firmware 6.0 and im running SipXecs 4.4... The weird 
thing is that nothing changes from call to call its just that some go through 
and some don't. Internal calling is working properly.
 
Help is greatly appreciated.
 
Regards,
 
--
Jorge E. Fernandez
IT Specialist
J9 IT Consultants

[email protected]
http://j9consultants.com - @jef2904




 

_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/
 
LAN/Telephony/Security and Control Systems Helpdesk:
Telephone: 434.984.8426
sip: [email protected]
 
Helpdesk Customers: http://myhelp.myitdepartment.net
Blog: http://blog.myitdepartment.net
 


NOTICE: This electronic mail message and any content within it are intended 
exclusively for the individual(s) or 
entities to which it is addressed. The message, together with any attachments 
and all other content, may contain
confidential and/or privileged information. Any unauthorized review, use, 
print, save, copy, disclosure or distribution
is strictly prohibited. If you have received this message in error, please 
immediately advise the sender by reply email
and delete all copies.
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/
 
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/
 
 


NOTICE: This electronic mail message and any content within it are intended 
exclusively for the individual(s) or 
entities to which it is addressed. The message, together with any attachments 
and all other content, may contain
confidential and/or privileged information. Any unauthorized review, use, 
print, save, copy, disclosure or distribution
is strictly prohibited. If you have received this message in error, please 
immediately advise the sender by reply email
and delete all copies.


NOTICE: This electronic mail message and any content within it are intended 
exclusively for the individual(s) or 
entities to which it is addressed. The message, together with any attachments 
and all other content, may contain
confidential and/or privileged information. Any unauthorized review, use, 
print, save, copy, disclosure or distribution
is strictly prohibited. If you have received this message in error, please 
immediately advise the sender by reply email
and delete all copies.
_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to