Firmware with a 3.3.x and above is a significant issue, and it is not
supported by sipXecs at all.   Prior to 3.3, you had to define all variables
in the phone.   With 3.3, all variables have a default definition in the
phone, many feature's variables are renamed, and in fact you have to run the
pre-3.3.x configuration through a tool that converts them.   Sipxecs doesn't
create a 3.3.x compatible configuration file.   If any of the phones you
have that aren't working are running on 3.3.x, you need to roll them back.

 

From: [email protected]
[mailto:[email protected]] On Behalf Of Shawn Beard
Sent: Friday, June 08, 2012 9:02 AM
To: Discussion list for users of sipXecs software
Subject: Re: [sipx-users] Directory and speed dial not loading

 

sipXecs 4.4.0- 2012-02-08EST08:58:30





I've tried Poycom versions  3.2.4, 3.2.6, 3.3.2 , 3.3.3. I know firmware
above 3.2.6 isn't support but thought I would give it a go. 

*****************************************

Shawn Beard

Enterprise Systems Engineer

Penn Manor School District

www.pennmanor.net <http://www.pennmanor.net/> 

(717)872-9500 x2354

 

 

From: Matt White <[email protected]>
Reply-To: Discussion list for users of sipXecs software
<[email protected]>
Date: Fri, 8 Jun 2012 12:00:50 -0400
To: <[email protected]>
Subject: Re: [sipx-users] Directory and speed dial not loading

 

Whats your sipx version and have you tried a different Polycom firmware?

-m

>>> Shawn Beard <[email protected]> 06/08/12 10:20 AM >>>

I should mention that I do see the speed dial entries in the
mac-directory.xml . This is my 8th speed dial entry and it doesn't show. If
I leave everything alone and just change the number to 4 digit it comes down
fine.     

 

<item>

       <ln><![CDATA[]]></ln>

       <fn><![CDATA[TestOutside]]></fn>

       <ct><![CDATA[17175551212]]></ct>

       <sd>8</sd>

       <rt />

       <dc />

       <ad>0</ad>

       <ar>0</ar>

       <bw>0</bw>

       <bb>0</bb>

     </item>

 

*****************************************

Shawn Beard

Enterprise Systems Engineer

Penn Manor School District

www.pennmanor.net <http://www.pennmanor.net/> 

(717)872-9500 x2354

 

 

From: shawn <[email protected]>
Reply-To: Discussion list for users of sipXecs software
<[email protected]>
Date: Fri, 8 Jun 2012 14:08:28 +0000
To: Discussion list for users of sipXecs software
<[email protected]>
Subject: Re: [sipx-users] Directory and speed dial not loading

 

I have issue narrowed down a bit. I can add as many speed dials as I want as
long as they are internal extensions. If I add any outside number or try to
do a directed pickup speed dial they bomb out. It looks like the directory
issue is just that the speed dials are killing the config file so the
directory never loads. If I push a config will all 4 digit speed dials then
the directory shows fine and so do the speed dials. I've tried changing
existing speed dials to outside numbers ie 917175551212 but upon pushing the
profile and rebooting I still see my old speed dial list. Any idea why I can
only have 4 digit internal speed dials ? This wasn't the case before
yesterday.

*****************************************

Shawn Beard

Enterprise Systems Engineer

Penn Manor School District

www.pennmanor.net <http://www.pennmanor.net/> 

(717)872-9500 x2354

 

 

From: Tony Graziano <[email protected]>
Reply-To: Discussion list for users of sipXecs software
<[email protected]>
Date: Thu, 7 Jun 2012 16:47:27 -0400
To: Discussion list for users of sipXecs software
<[email protected]>
Subject: Re: [sipx-users] Directory and speed dial not loading

 

You have to send profiles and reboot the phones in order for them to load...

On Thu, Jun 7, 2012 at 3:36 PM, Shawn Beard <[email protected]> wrote:

I deployed about 25 Polycom 550's this morning running 3.2.6 . Some of them
have directories, some don't. None of them can see speed dials beyond the 3
on the line buttons. If they hit the up arrow they don't see any speed
dials. The mac-directory.xml files are fully populated.  Any ideas ?

 

Thanks

 

 

*****************************************

Shawn Beard

Enterprise Systems Engineer

Penn Manor School District

www.pennmanor.net <http://www.pennmanor.net/> 

(717)872-9500 x2354

 


_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/





 

-- 
~~~~~~~~~~~~~~~~~~
Tony Graziano, Manager
Telephone: 434.984.8430
sip: [email protected]
Fax: 434.465.6833
~~~~~~~~~~~~~~~~~~
Linked-In Profile:
http://www.linkedin.com/pub/tony-graziano/14/4a6/7a4
Ask about our Internet Fax services!
~~~~~~~~~~~~~~~~~~

LAN/Telephony/Security and Control Systems Helpdesk:

Telephone: 434.984.8426

sip: [email protected]

 

Helpdesk Customers: http://myhelp.myitdepartment.net

Blog: http://blog.myitdepartment.net

_______________________________________________ sipx-users mailing list
[email protected] List Archive:
http://list.sipfoundry.org/archive/sipx-users/ 

_______________________________________________ sipx-users mailing list
[email protected] List Archive:
http://list.sipfoundry.org/archive/sipx-users/ 

_______________________________________________
sipx-users mailing list
[email protected]
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to