Dear Markus, Dr. Markus Stöhr <[email protected]> writes:
> Currently, we have backfilling enabled, but without any parameters. If your MaxTime is greater than 1 day, you might find that backfilling does not work properly if no parameters are set. In this case, you will probably have to set bf_window (default: 1 day) to something similar to MaxTime. Cheers, Loris -- This signature is currently under construction.