Thanks! We have set bf_window now to 3 days ;-).

On 10/07/2015 08:55 AM, Loris Bennett wrote:

Dear Markus,

Dr. Markus Stöhr <[email protected]>
writes:

Currently, we have backfilling enabled, but without any parameters.

If your MaxTime is greater than 1 day, you might find that backfilling
does not work properly if no parameters are set.  In this case, you will
probably have to set bf_window (default: 1 day) to something similar to
MaxTime.

Cheers,

Loris



--
=====================================================
Dr. Markus Stöhr
Zentraler Informatikdienst BOKU Wien / TU Wien
Wiedner Hauptstraße 8-10
1040 Wien

Tel. +43-1-58801-420754
Fax  +43-1-58801-9420754

Email: [email protected]
=====================================================