We have not been using Smartbridges for long but of the 5 truck rolls this
month we have had:

A ABO that wouldn't associate - config problem with the Cisco AP.

A ABT that associated with the customers internal Linksys after a generator
test.

A ABO that we didn't waterproof the N connector on.

A ABT that was working fine but the customers Linksys router reset to
factory config after a power outage.

ABO that wouldn't associate - Cisco 350AP locked up.

Of the 5 truck rolls none were Smartbridges fault,  3 were our fault, and 2
were Cisco problems.

We have (knock on plastic) not had any hardware failures.

Mark Radabaugh
Amplex
(419) 720-3635


The PART-15.ORG smartBridges Discussion List
To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe smartBridges 
<yournickname>
To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe smartBridges)
Archives: http://198.63.203.6  

Reply via email to