Scott, Thanks again. I'll download that utility and make a roll to those customers who use the SB equipment...
I was wondering if 172 was a harmonic of 2.4 Ghz...and yes, this is a 3 element vertically polarized yagi, but it resides no more than 25 feet from my radio cards...the AP and cards are on the inside of the building, while this yagi is on the outside...but it is pointed in the general direction of my AP (maybe 20 degrees off). So, I guess my questions are this: 1) Could I sheild my AP from this unwanted freq? 2) Should I disconnect the amp and see if that remedies things? This is so frustrating! My network is completely down right now because of this... JOHN Quoting shoffman <[EMAIL PROTECTED]>: > John, > > On the SB stuff you use simpledeploy. A utility from sB, but it has a > flaw... you must be connected to the AB unit via the wire side... does > not work on the wireless side. They state they did this for security > issues, but I ca not see why CPE would have a security issue with this > feature(AP's yes.. CPE, uhm..what is a customer or foe going to do burn > in the wrong channel? Doubt it..) > > 172 MHz is a harmonic of the 2.4 spectrum.. but a Yagi is pretty > directional, so I don't think it would screw you too badly... Doubt that > is your issue. > > Not sure what the default is on sb stuff on preamble. will have to look > at one... > > I still think what you are dealing with is either a hosed tranmitter (or > amplifier) or pure interference... preamble would not cause the issue > you are dealing with (on both WET-11's and SB gear).. > > Scott > > > > > -----Original Message----- > From: "John K. McReynolds" <[EMAIL PROTECTED]> > To: [EMAIL PROTECTED] > Date: Tue, 25 Nov 2003 10:02:26 -0600 > Subject: Re: [smartBridges] Hosed network > > > Scott, > > Thanks for the info...how does one "burn" the AP's name as the default > > config? > > > > I am using the default pre-amble...whatever that is. Haven't changed > > this. If > > this wasn't set correctly, could it hose the AP? > > > > And yes, my first concern was that of signal issues. I noticed a > > vertically > > polarized Yagi down on the roof of the shed at the tower (all of our > > stuff is > > at the top of the tower). Upon further inspection, I found that it > > operates > > near 172 Mhz...could this be interfering with our stuff? I really hope > > not... > > > > Also, we have an amp on our omni antenna. The injector for this is > > down in the > > shed. I wonder if the amp is flaking out? I guess I could just bypass > > the > > injector and go straight into the card...effectively turning "off" the > > amp. > > > > Many thanks, > > > > JOHN > > > > Quoting shoffman <[EMAIL PROTECTED]>: > > > > > John, > > > > > > You are losing association. Thats plane and simple. The ABO's do > > that > > > crap if they lose association and can't re-associate quickly (they > > change > > > their ESSID to garbage).. Thats why we started burning in the AP's > > name > > > as the default config.. But as far as I know.. ABO's going like this > > do > > > not affect the AP's (We use Cisco and we didn't see this crap). > > > > > > What Pre-amble length are you using. On the Cisco's (per AB's > > > suggestion) we switched to long and it helped... but the fact that > > you > > > WET-11 light is blinking indicates I think you are having signal > > issues. > > > > > > Scott > > > > > > > > > -----Original Message----- > > > From: "John K. McReynolds" <[EMAIL PROTECTED]> > > > To: [EMAIL PROTECTED] > > > Date: Tue, 25 Nov 2003 08:58:57 -0600 > > > Subject: [smartBridges] Hosed network > > > > > > > This will start off-topic, but then get back on topic... > > > > > > > > We have an Orinoco AP2000 at a water tower. We have one radio card > > in > > > > this > > > > unit. We also have a YDI ECII acting as the backhaul. The two > > units > > > > are > > > > connect via eachother's ethernet ports. No switch or router in > > > > between. This > > > > has worked great for sometime now...until the last week or so. > > > > > > > > About a week ago, we started noticing a massive slow down on our > > > > network...then > > > > the AP could not be reached with a ping or any admin tools...i.e., > > the > > > > network > > > > was down. So, figuring maybe it was equipment failure, I replaced > > all > > > > the AP > > > > equipment at the tower...different AP2000, different card, > > different > > > > coax > > > > jumper...and bang! It was back to normal. I did change channels > > > > however. > > > > > > > > Now, here we are a week later (today). Same thing is happening. > > > > > > > > We have WET11's and ABO's as CPE on our network. I personally have > > a > > > > WET11 at > > > > my home...the WAN light now comes and goes...this morning it is > > totally > > > > off. > > > > > > > > We have also noticed that after the first "outage", the ABOs had > > lost > > > > association and upon further inspection, the AP that each was > > > > associated with > > > > was just a bunch of random garbage...like sHOFW3EHNFSALX, instead > > of > > > > the name > > > > of our AP. We re-associated them and they worked fine. > > > > > > > > So, time for my questions: > > > > 1) Is there some setting that the ABOs need to have to "play nice" > > with > > > > an > > > > AP2000? > > > > 2) If an ABO freaks out and loses its association, could it hose > > the > > > > AP2000 > > > > also? > > > > 3) Should I put a switch or router between the ECII and the AP2000? > > > > > > > > I am really in need of assistance here...I am about to my ropes end > > > > with this > > > > stuff...any pointers or suggestions will be more than welcomed. > > > > > > > > Many thanks in advance, > > > > > > > > JOHN > > > > The PART-15.ORG smartBridges Discussion List > > > > To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe > > > > smartBridges <yournickname> > > > > To Remove: mailto:[EMAIL PROTECTED] (in the body type > > unsubscribe > > > > smartBridges) > > > > Archives: http://archives.part-15.org > > > > > > The PART-15.ORG smartBridges Discussion List > > > To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe > > smartBridges > > > <yournickname> > > > To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe > > > smartBridges) > > > Archives: http://archives.part-15.org > > > > > > > > > John K. McReynolds > > > > WinfieldMO.net > > PO Box 126 > > Winfield, MO 63389 > > (636) 668-6141 > > http://www.winfieldmo.net > > The PART-15.ORG smartBridges Discussion List > > To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe > > smartBridges <yournickname> > > To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe > > smartBridges) > > Archives: http://archives.part-15.org > > The PART-15.ORG smartBridges Discussion List > To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe smartBridges > <yournickname> > To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe > smartBridges) > Archives: http://archives.part-15.org > John K. McReynolds WinfieldMO.net PO Box 126 Winfield, MO 63389 (636) 668-6141 http://www.winfieldmo.net The PART-15.ORG smartBridges Discussion List To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe smartBridges <yournickname> To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe smartBridges) Archives: http://archives.part-15.org