It looks like the tests are not implemented with the known syntax.

C:\Program Files\smartmontools\bin>smartctl -a sda
smartctl version 5.38 [i686-mingw32-vista-sp1] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     00AACS-00ZUB
Serial Number:    [No Information Found]
Firmware Version: 01.0
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   3
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Tue Sep 09 23:21:45 2008 MS
SMART support is: Available - device has SMART capability.
                  Enabled status cached by OS, trying SMART RETURN STATUS cmd.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
                                        was suspended by an interrupting command
 from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed

                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 (13980) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off supp
ort.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 163) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_
FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   200   198   000    Pre-fail  Always       -
       0
  3 Spin_Up_Time            0x0003   158   158   000    Pre-fail  Always       -
       5058
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -
       92
  5 Reallocated_Sector_Ct   0x0033   200   200   000    Pre-fail  Always       -
       0
  7 Seek_Error_Rate         0x000e   200   200   000    Old_age   Always       -
       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -
       189
 10 Spin_Retry_Count        0x0012   100   253   000    Old_age   Always       -
       0
 11 Calibration_Retry_Count 0x0012   100   253   000    Old_age   Always       -
       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -
       89
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -
       15
193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always       -
       813
194 Temperature_Celsius     0x0022   107   100   000    Old_age   Always       -
       40
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -
       0
197 Current_Pending_Sector  0x0012   200   200   000    Old_age   Always       -
       0
198 Offline_Uncorrectable   0x0010   100   253   000    Old_age   Offline      -
       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -
       0
200 Multi_Zone_Error_Rate   0x0008   100   253   000    Old_age   Offline      -
       0

Error SMART Error Log Read failed: Function not implemented
Smartctl: SMART Error Log Read Failed
Error SMART Error Self-Test Log Read failed: Function not implemented
Smartctl: SMART Self Test Log Read Failed
Error SMART Read Selective Self-Test Log failed: Function not implemented
Smartctl: SMART Selective Self Test Log Read Failed

C:\Program Files\smartmontools\bin>


-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to