Markus Trippelsdorf wrote:
>  On Sat, Mar 21, 2009 at 06:43:37PM +0100, Christian Franke wrote:
>> Markus Trippelsdorf wrote:
>> > I could find no data sheet on the web. Most attributes
>> > make no sense without documentation. Someone should contact
>> > Indilinx and ask for a description of the values.
>> >
>> >   
>> 
>> Looks like even the general data format of the attributes part is broken.
>> (In the ATA Standard, this is a "Vendor Specific" black box in the SMART 
>> data block).
> 
> Yes, and it will be hard to figure out what the attributes mean without
> help from the vendor.

There is some information available from the vendor, see
http://www.ocztechnologyforum.com/forum/showthread.php?t=57898&highlight=crystal

BTW, the same controller is also being used now in a number of other products:
     * Corsair: "Extreme Series"
     * SuperTalent: "Ultradrive"
     * Gskill: "Falcon"
     * Patriot Memory: "Torqx"
     * Mushkin: "Europe 2"

On our OCZ vertex drive, I do see a reasonable value for "remaining life time"
(Attribute 209), but the value for "Erase count Average" seems to "overflow",
once it rises > 255, it becomes 0 again... any idea how to fix this?

Local output of smartctl -a below:
> smartctl version 5.37 [x86_64-redhat-linux-gnu] Copyright (C) 2002-6 Bruce 
> Allen
> Home page is http://smartmontools.sourceforge.net/
> 
> === START OF INFORMATION SECTION ===
> Device Model:     OCZ-VERTEX
> Serial Number:    I4SPN7IC949UOPC2H195
> Firmware Version: 1.30
> User Capacity:    256,060,514,304 bytes
> Device is:        Not in smartctl database [for details use: -P showall]
> ATA Version is:   7
> ATA Standard is:  Exact ATA specification draft version not indicated
> Local Time is:    Mon Jul 27 22:05:10 2009 CEST
> SMART support is: Available - device has SMART capability.
> SMART support is: Enabled
> 
> === START OF READ SMART DATA SECTION ===
> SMART overall-health self-assessment test result: PASSED
> See vendor-specific Attribute list for marginal Attributes.
> 
> General SMART Values:
> Offline data collection status:  (0x00) Offline data collection activity
>                                         was never started.
>                                         Auto Offline Data Collection: 
> Disabled.
> Self-test execution status:      (   0) The previous self-test routine 
> completed
>                                         without error or no self-test has 
> ever 
>                                         been run.
> Total time to complete Offline 
> data collection:                 (   0) seconds.
> Offline data collection
> capabilities:                    (0x1d) SMART execute Offline immediate.
>                                         No Auto Offline data collection 
> support.
>                                         Abort Offline collection upon new
>                                         command.
>                                         Offline surface scan supported.
>                                         Self-test supported.
>                                         No Conveyance Self-test supported.
>                                         No Selective Self-test supported.
> SMART capabilities:            (0x0003) Saves SMART data before entering
>                                         power-saving mode.
>                                         Supports SMART auto save timer.
> Error logging capability:        (0x00) Error logging NOT supported.
>                                         General Purpose Logging supported.
> Short self-test routine 
> recommended polling time:        (   0) minutes.
> Extended self-test routine
> recommended polling time:        (   0) minutes.
> 
> SMART Attributes Data Structure revision number: 16
> Vendor Specific SMART Attributes with Thresholds:
> ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
> WHEN_FAILED RAW_VALUE
>   1 Raw_Read_Error_Rate     0x0000   008   000   000    Old_age   Offline  
> In_the_past 0
>   9 Power_On_Hours          0x0000   060   010   000    Old_age   Offline     
>  -       0
>  12 Power_Cycle_Count       0x0000   001   000   000    Old_age   Offline  
> In_the_past 0
> 184 Unknown_Attribute       0x0000   232   000   000    Old_age   Offline  
> In_the_past 0
> 195 Hardware_ECC_Recovered  0x0000   005   000   000    Old_age   Offline  
> In_the_past 0
> 196 Reallocated_Event_Count 0x0000   000   000   000    Old_age   Offline  
> FAILING_NOW 0
> 197 Current_Pending_Sector  0x0000   000   000   000    Old_age   Offline  
> FAILING_NOW 0
> 198 Offline_Uncorrectable   0x0000   238   096   000    Old_age   Offline     
>  -       522900
> 199 UDMA_CRC_Error_Count    0x0000   070   199   000    Old_age   Offline     
>  -       475082
> 200 Multi_Zone_Error_Rate   0x0000   055   087   000    Old_age   Offline     
>  -       22931
> 201 Soft_Read_Error_Rate    0x0000   058   216   000    Old_age   Offline     
>  -       21869
> 202 TA_Increase_Count       0x0000   086   188   000    Old_age   Offline     
>  -       4
> 203 Run_Out_Cancel          0x0000   241   187   000    Old_age   Offline     
>  -       3
> 204 Shock_Count_Write_Opern 0x0000   000   000   000    Old_age   Offline  
> FAILING_NOW 0
> 205 Shock_Rate_Write_Opern  0x0000   160   134   000    Old_age   Offline     
>  -       1
> 206 Flying_Height           0x0000   001   000   000    Old_age   Offline  
> In_the_past 0
> 207 Spin_High_Current       0x0000   192   029   000    Old_age   Offline     
>  -       0
> 208 Spin_Buzz               0x0000   059   004   000    Old_age   Offline     
>  -       0
> 209 Offline_Seek_Performnce 0x0000   099   000   000    Old_age   Offline  
> In_the_past 0
> 210 Unknown_Attribute       0x0000   238   000   000    Old_age   Offline  
> In_the_past 0
> 211 Unknown_Attribute       0x0000   000   000   000    Old_age   Offline  
> FAILING_NOW 0
> 
> Warning: device does not support Error Logging
> Warning! SMART ATA Error Log Structure error: invalid SMART checksum.
> SMART Error Log Version: 1
> No Errors Logged
> 
> Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
> SMART Self-test log structure revision number 1
> No self-tests have been logged.  [To run self-tests, use: smartctl -t]
> 
> 
> Device does not support Selective Self Tests/Logging

Regards,

Peter Niemayer



------------------------------------------------------------------------------
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day 
trial. Simplify your report design, integration and deployment - and focus on 
what you do best, core application coding. Discover what's new with 
Crystal Reports now.  http://p.sf.net/sfu/bobj-july
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to