At 11:22 AM 9/28/2010, Joao Pedras wrote:

>The drill usually is: monitoring tools make me aware a host being down,
>I try the console with no luck. When I power cycle it the red led stays
>on. Replacing the ac adapter fixes it.

Yes, this has been our experience as well.  These were deployed about 
a year ago.  New power supply fixes the issue.

         ---Mike


>My 2 cents.
>
>Joao
>
>On 9/28/10 6:59 AM, Mike Tancsa wrote:
> > At 05:37 PM 9/22/2010, Soren Kristensen wrote:
> >> Our experience is that 9 out of 10 times issues with stability is either
> >> problems with the power supply or
> >
> >
> > Hi,
> >          Have there been any bad batches of power supplies in the
> > past ?  We have had a lot of failures all related to power
> > supplies.  Most of the times, they start to put out inadequate
> > voltage over time.
> >
> >          ---Mike
> >
> >
> > --------------------------------------------------------------------
> > Mike Tancsa,                                      tel +1 519 651 3400
> > Sentex Communications,                            [email protected]
> > Providing Internet since 1994                    www.sentex.net
> > Cambridge, Ontario Canada                         www.sentex.net/mike
> >
> > _______________________________________________
> > Soekris-tech mailing list
> > [email protected]
> > http://lists.soekris.com/mailman/listinfo/soekris-tech

--------------------------------------------------------------------
Mike Tancsa,                                      tel +1 519 651 3400
Sentex Communications,                            [email protected]
Providing Internet since 1994                    www.sentex.net
Cambridge, Ontario Canada                         www.sentex.net/mike