Dear all,

in some cases, XPRESS wrongly assigns "heavy" and "light" states for
some peptides. This results of course in inverted, wrong ratios.
"heavy" and "light" are correctly assigned by ASAP and verified by
checking with Pep3d.
We are using differential formaldehyde labeling. This problem occurs
with both static and variable modifications for  "heavy" and "light"
dimethylation. It occurs for a few peptides (not all), we cannot see
any regularity.

I would greatly appreciate some assistance!

Thanks

Oliver

-- 