So, after conducting some "observations" this afternoon, I have concluded that the axle pump is more of a load than my loco can handle in its current configuration. I have two choices : make the fire bigger, or increase the cylinder bore (there are undoubtedly other options, of which I am sure to hear). So my question is: would increasing the cylinder bore increase or decrease steam consumption under load? The idea is that increasing the cylinder bore would increase the work that could be done with a given amount of steam. Or would the increased swept area just increase the steam consumption?
royce in SB do I get points for posting questions that get people thinking ? Royce wrote: >[EMAIL PROTECTED] wrote: > > > >>I would recommend never adding any chemicals to the boiler at all to avoid >>scale buildup and other problems. >> >> >> >> >Well, you are preaching to the choir at this point. But after some >experiments this evening, I'm beginning to think that the problem is >that the load of the axle pump pumping water exceeds the firing capacity >of the locomotive/boiler. I'm going to have to get a bigger kick. And >that's going to be another story. >Thanks for sharing. > >royce in SB >_______________________________________________ > > _______________________________________________ SSLiveSteam mailing list Send messages: [email protected] Cancel subscription: http://postfix.45mm.com/mailman/listinfo/sslivesteam Rules: http://www.45mm.com/sslivesteam_guide.html