So, after conducting some "observations" this afternoon, I have 
concluded that the axle pump is more of a load than my loco can handle 
in its current configuration.  I have two choices : make the fire 
bigger, or increase the cylinder bore (there are undoubtedly other 
options, of which I am sure to hear).  So my question is: would 
increasing the cylinder bore increase or decrease steam consumption 
under load?  The idea is that increasing the cylinder bore would 
increase the work that could be done with a given amount of steam.  Or 
would the increased swept area just increase the steam consumption?

royce in SB

do I get points for posting questions that get people thinking ?


Royce wrote:

>[EMAIL PROTECTED] wrote:
>
>  
>
>>I would recommend never adding any chemicals to the boiler at all to avoid  
>>scale buildup and other problems. 
>> 
>>
>>    
>>
>Well, you are preaching to the choir at this point.  But after some 
>experiments this evening, I'm beginning to think that the problem is 
>that the load of the axle pump pumping water exceeds the firing capacity 
>of the locomotive/boiler.  I'm going to have to get a bigger kick.  And 
>that's going to be another story.
>Thanks for sharing.
>
>royce in SB
>_______________________________________________
>  
>

_______________________________________________
SSLiveSteam mailing list
Send messages: [email protected]
Cancel subscription: http://postfix.45mm.com/mailman/listinfo/sslivesteam
Rules: http://www.45mm.com/sslivesteam_guide.html

Reply via email to