Hello Royce, Have you tried just running with the by-pass slightlyn opened, to returna portion of the pumps output to the water tank? You can throttle the pumps out put down so that only a little bit is getting into the boiler, then gradually close the by pass until you balance the feed to what the boiler uses in running. By adjusting the bypass, you can make the load of the pump whatever you wish, and not have to mess with the burner or cylinder bores. The method of running where you are either send ALL of the water to the boiler, or none of it to the boiler is actually very hard on the boiler, as everytime you close the bypass and feed all of the pumps output to the boiler, you cool the water in the boiler massively. It's a LOT better to feed just a little all the time, tan to be constantly opening and closing the valve. Keith ----- Original Message ----- From: "Royce" <[EMAIL PROTECTED]> To: "Small-scale live steam discussions" <[email protected]> Sent: Sunday, October 29, 2006 9:57 PM Subject: Re: [SSLiveSteam] Boiler crud
> So, after conducting some "observations" this afternoon, I have > concluded that the axle pump is more of a load than my loco can handle > in its current configuration. I have two choices : make the fire > bigger, or increase the cylinder bore (there are undoubtedly other > options, of which I am sure to hear). So my question is: would > increasing the cylinder bore increase or decrease steam consumption > under load? The idea is that increasing the cylinder bore would > increase the work that could be done with a given amount of steam. Or > would the increased swept area just increase the steam consumption? > > royce in SB > > do I get points for posting questions that get people thinking ? > > > Royce wrote: > >>[EMAIL PROTECTED] wrote: >> >> >> >>>I would recommend never adding any chemicals to the boiler at all to >>>avoid >>>scale buildup and other problems. >>> >>> >>> >>> >>Well, you are preaching to the choir at this point. But after some >>experiments this evening, I'm beginning to think that the problem is >>that the load of the axle pump pumping water exceeds the firing capacity >>of the locomotive/boiler. I'm going to have to get a bigger kick. And >>that's going to be another story. >>Thanks for sharing. >> >>royce in SB >>_______________________________________________ >> >> > > _______________________________________________ > SSLiveSteam mailing list > Send messages: [email protected] > Cancel subscription: http://postfix.45mm.com/mailman/listinfo/sslivesteam > Rules: http://www.45mm.com/sslivesteam_guide.html > _______________________________________________ SSLiveSteam mailing list Send messages: [email protected] Cancel subscription: http://postfix.45mm.com/mailman/listinfo/sslivesteam Rules: http://www.45mm.com/sslivesteam_guide.html