Could it be that the Target's "NOP In (0x20)" are incrementing StatSN, when the Microsoft Initiator, thinks it should not be doing so?
In the trace I'm currently looking at, I see the solaris target sending the following sequence of (4) packets: #1 - "SCSI Data In", StatSN = 0x2a #2 - "NOP In", StatSN = 0x2b #3 - "NOP In", StatSN = 0x2c #4 - "SCSI Data In", StatSN = 0x2d ...At which point the Microsoft Initiator says: Invalid status seq num 0x2d. Current is 0x2b Thanks Nigel This message posted from opensolaris.org _______________________________________________ storage-discuss mailing list [email protected] http://mail.opensolaris.org/mailman/listinfo/storage-discuss