> On Feb 20, 2016, at 8:36 PM, Rick Walsh <[email protected]> wrote: > A little bit of data validation would be nice. One dive was to -20m, another > I was breathing 50/60, and another EAN120. Unlikely a real user would enter > such values, so not worth holding up a release, but it'd be nice to pick up > on impossible values.
Please try -874 (on downloads/daily and in Google Play in a little while) negative depth and duration are rejected (actually, you can't even enter a '-') illegal gas mixes are rejected; once again you can't even enter them (but this needs some SERIOUS testing, please - I'd hate to see it reject valid combinations) some sanity checks on depth (besides no negative values, depths below 500m are silently ignored) > On one dive, I entered air temperature as 50F, but it was saved as 50C. > Entering depth as 60ft, it was correctly converted to 18.3m. My locale is > metric. I still cannot reproduce this. Very strange. 50F gives me 10.0°C as one would expect. But I made it even more flexible and allowed upper and lower case letters. And there isn't even a test for "°" so I have no idea how °F can work and F doesn't... > I was a bit disappointed not to be able to delete my bogus dives from > Subsurface-mobile. Would that be hard to implement? This I don't think I'll get to tonight. /D _______________________________________________ subsurface mailing list [email protected] http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface