Am 25.02.13 09:46, schrieb Paul Evans:
Hi,
Sure I am missing something obvious but I cannot seem to get parms read
by the DTU.

We are using some Sun Ray 1's as information points in the museum,
running various slideshows in kiosk.

Managed to get everything up and running without too much trouble but
they go into Power Off after about 5 minutes.


Sun Ray 1 does not have a poweroff feature...

I've tried everything suggested by reading the various blogs, firmware
updates work fine but it does not read the .parms. Trying to set
poweroff=400 so that I can use crontab to reset everything at 9am and
they will power off when the museum closes at 5pm.


The 'poweroff' setting only applies to Sun Ray 3 series DTUs.

What you are probably seeing is screen blanking. The best discussion of this, with all bells and whistles, is surely <https://blogs.oracle.com/ThinkThin/entry/one_blank_to_rule_them>.


Is there a way of making the DTU just read the .parms?


If you still care about this: could you post utquery results for one of your DTUs?

- Jörg


--
Jörg Barfurth                     http://blogs.oracle.com/joergb

Disclaimer: I am employed by Oracle. The statements and opinions
expressed here are my own and do not necessarily represent those
of Oracle Corporation.
_______________________________________________
SunRay-Users mailing list
[email protected]
http://www.filibeto.org/mailman/listinfo/sunray-users

Reply via email to