Hey there,

On Fri, Oct 8, 2010 at 4:55 PM, Andy Graybeal
<[email protected]>wrote:

> Greetings,
> I need some help wrapping my head around how to be redundant.
>
> I'll have 2 firewalls, and 2 UPS's one for each firewall.
>
> Each firewall will have:
> 1. a hot swap raid array (only two HD's set to RAID 1, mirroring).
> 2. two hot swap power supplies.
>
> Is one UPS per firewall agreeable?  I don't know how to do it otherwise.  I
> can't imagine purchasing 4 UPS's, one for each power supply.  Seems a little
> overkill. I welcome any input.
>

Plug one hotswap supply from each firewall into both of the UPS boxes you
have. That way, even if you have to service a UPS, you won't lose a
firewall. I wouldn't dedicate a UPS to
each firewall, because any UPS issue makes your bring down a box no matter
what.

Make sense?

Gerald.

Reply via email to