Hi Per,
You wrote:
> I got my both Compaq Deskpro 286 running on
> penlightbatteries,
Alright!
> but I still have one problem. From one
> of the systems I can not reach the serial or parallel
> ports (one of each). I have tried most things, I have
> compared all jumpersettings,
I don't know about the parallel port but the comport may
have the wrong jumper setting.
> I have MS-DOS 5 and com1 on IRQ3. The diagnostic program
> says com1 os OK, it is not. I also can not load the
> mousedriver.
Com1 should be IRQ4 for normal DOS use.
BTW, if it was previously set to com2/IRQ3 and a com1 card
was removed, then DOS would call it com1 now since it
names them in order. You may remember this as one of the
most common newbie problems with Arachne.
Cheers,
Ole Juul