I am not sure in the case of the E250. Does it have a keyboard and framebuffer? I had to comment out all tty gettys on the Netra t1 to get rid of the messages. The t1 only uses one serial port for getty.
> _________________________________________________________ > Davin Carter > Wall Street On Demand > > [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> > phone 303.417.9999 x205 > fax 303.440.2982 > > > -----Original Message----- From: Anand Buddhdev [mailto:[EMAIL PROTECTED]] Sent: Sunday, June 23, 2002 10:13 AM To: [EMAIL PROTECTED] Subject: Re: [suse-sparc] init cannot open ttys On Fri, Jun 21, 2002 at 12:55:32PM +0200, Anand Buddhdev wrote: Doesn't anyone know the answer to this? > I am running Suse 7.3 sparc on an E250. I saw this in my messages > file today: > > Jun 20 02:04:18 dali mingetty[1340]: /dev/tty4: cannot open tty: No such device > Jun 20 02:04:19 dali init: Id "4" respawning too fast: disabled for 5 minutes > > This is happening with the other 5 ttys as well. It never used to > happen. However, yesterday, the server was relocated to another site, > and now it has no keyboard or monitor connected to it. > > I stopped the messages, by commenting out the tty lines in > /etc/inittab. Did I do the right thing, or is there a better solution > to this problem? -- Anand Buddhdev http://anand.org -- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED] -- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED]