On Tue, Oct 4, 2016 at 1:22 PM, Matt Hoppes < [email protected]> wrote:
> > If so, is there a way around this so a customer does not have to reboot > the CPE? When an IMSI is blacklisted, does this mean it isn't available for a detach? I haven't seen this problem yet, as far as I know. I'm still trying to explain why a UE should jump from 50-60 megs down, to 2, on a lightly loaded sector. I've been testing the 8000 on a 2x4 sector today. This is somewhat similar behavior to what we get daily complaints about — it appears to affect customers somewhat randomly, and there is no cure but to wait. (I'm not about to reset the EPC.) I had hoped I wouldn't see it on the 8000, but so far I may be. Other than that, RF performance on the 8000 is good. I'm consistently hitting high modulations and 6-7 Mbps on the upstream. -- Jeremy Austin (907) 895-2311 (907) 803-5422 [email protected] Heritage NetWorks Whitestone Power & Communications Vertical Broadband, LLC Schedule a meeting: http://doodle.com/jermudgeon
_______________________________________________ Telrad mailing list [email protected] http://lists.wispa.org/mailman/listinfo/telrad