Hi Steve, Thanks for this information.
We are running an "Advanced" version of 6.2.5, which I believe is the same as Pro. I have 3 other instances setup on the server but am only running one while we test this issue. I just tried to run the Terascript server as the local Administrator on the box (just to see if privs were an issue) and that produced the same results: server appears to execute the STARTUPURL but then crashes and tries multiple restarts before stopping. I also create another local user and gave it rights to Tronics directory, no dice. Put it in the Administrators group, no dice. All our other servers run as "Local System." May I ask what user you run your service as? What permissions they have? Yes, we can run the STARTUPURL .taf from a web browser without a problem. I can also run it from a web browser on the application server itself. I have created a .taf with an empty ResultsHTML action in it. That doesn't work either. Very strange. Any other suggestions are welcome. Thank you for you help. - Matt [email protected] writes: >Hi Matt, > >We have been running STARTUPURL for over a year on our server. Same setup >as you. 64 bit Windows 2008 R2 server. > >Three things potentially different. > >We are running the pro version with 4 instances running on the same >server. > >We have not updated our server to the most current version. I believe we >are using 6.2.1. > >We are not running the Terascript services as “Local System”. We are >logging in as a different account. > >I assume you can run the taf successfully from a browser on the server. > >Let me know if you have any other questions. > >Steve Fogelson >Internet Commerce Solutions > > > > > >From: Tango-Talk [mailto:[email protected]] >Sent: Friday, April 12, 2013 3:04 PM >To: [email protected] >Subject: TeraScript-Talk: Terascript 6 STARTUPURL error > > > > > >Does anyone run a .taf file by way of the server.ini STARTUPURL setting? > >Our Terascript 6.2.x install crashes on startup when we have a .taf file >set to STARTUPURL. We have used this setting since the beginning of time >with Witango to have the app server do some maintence, drive mapping, >etc. when it starts up. > >Here's what you'll see in events.log on T6 when it crashes on the >execution of STARTUPURL. It attempts to restart. The Terascript.log file >will show multiple attempts at trying to restart before it quits. When we >remove the STARTUPURL from the server.ini it starts right up. We've done >some debugging with Robert but he'd can't reproduce this. Would anyone >mind dropping a URL to a .taf file in their TeraScript 6 STARTUPURL >setting in server.ini to see if they can reproduce. > >[ 4992] 2013-03-22 15:36:27 START INFO Startup URL: >Sent [ http://dcet6.brattle.harvard.edu/common/gowstrt.taf >]http://dcet6.brattle.harvard.edu/common/gowstrt.taf, waiting for 60 >seconds >[ 4992] 2013-03-22 15:36:28 RUNTIME INFO Attempting restart > >Our T6 app server is running on a 64-bit Windows 2008 R2 server. The >Terascript service is running as "Local System." > >Much thanks, >- Matt > >________________________________________________ >Matt Muro >Web Services Manager, Senior Web Developer >Harvard University Division of Continuing Education > > > > >=========================================================================== > >To unsubscribe from this list, please send an email to [ >mailto:[email protected] ][email protected] with "unsubscribe >terascript-talk" in the body. > > >--------------------------------------------------------------------------- >To unsubscribe from this list, please send an email to [ >mailto:[email protected] ][email protected] with "unsubscribe >terascript-talk" in the body. ---------------------------------------- To unsubscribe from this list, please send an email to [email protected] with "unsubscribe terascript-talk" in the body.