"Skip Withrow" <[EMAIL PROTECTED]> wrote: > I have recently acquired a Datum TS2100-IRIG NTP time server. Nice > unit, and I do have IRIG-B to feed it, however, reading the manual I > notice that there is a GPS version as well. Upon taking the top of the > unit off I notice that there are the connector and standoffs for both > Oncore > and Trimble ACE-III sized receivers. Tried plugging both in, but the > unit > does not > seem to recognize it (always reports GPS receiver busy).
I was able to make this conversion with an ACE-III module (thanks Jason!). I am a bit fuzzy on the details now and my notebooks are packed away in some random box, but I do recall that it was important to set the ACE-III to speak the right protocol -- TSIP, IIRC. There may have been an issue with speed as well. A logic analyzer on the TS's Tx pin was helpful. I have a vague memory of sending out a note about my successful conversion, so you may want to check the archives. What I am certain of is that Symmetricom is not going to be of any help. Abandon all hope there. -ch _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.