A lot depends upon the temperature sensor in the Tbolt. Dallas Semi changed
the guts of the sensor ship in such a way that the Tbolt can only get 1 degree
resolution out of it. Later production Tbolts all have that sensor. Does
your Tbolt show a mostly flat line temp curve with coarse, step-like
transitions or one that tracks the temperature rather finely? When you hit
the thing with the hot air, what did the temperature plot do?
Also, the temperature sensor would do no good inside the OCXO (there is
already one in there). The Tbolt temperature sensor is used to compensate the
unit for temperature effects on the unit as a complete system. It is also
used for environmental alarms, etc.
----------------------------------------