Make sure that the 1 PPS output is enabled... It can be turned off by
software and that mode can be set in EEPROM.
Also, many scopes have great difficulty showing a 10 uS pulse at a 1 PPS rep
rate. Digital scopes might not sample it in normal display modes (envelope or
glitch capture mode can help). It can easily get lost on an analog display...
_________________________________________________________________
Your E-mail and More On-the-Go. Get Windows Live Hotmail Free.
http://clk.atdmt.com/GBL/go/201469229/direct/01/
_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.