Dear Bert and all,

maybe I missed it, but how can a linear regulator filter out transients from a switched PSU? The cited LT1764A has less than 30dB Suppression at 100 kHz getting worse for higher frequencies.Even the famous 7805 had only 50 dB suppression. For going to a real clean PSU, I would expect some old-school filtering and screening should be fine.. or am I wrong?

A classic 50/60 Hz all linear PSU has a bad efficiency, but very little high frequency spurs to care about. For my current project (GPSDO with double oven HP10811), I will only use those.. even the classic LED 7-segment display I am planning to use will not use multiplexed mode but quasi-static (1 Hz update rate only).

Regards,
Achim

_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to