On 05/08/2012 11:58 PM, Bob Camp wrote:
Hi

The first thing to check is the soldering job on the DB-9 connector. Second 
thing to check is the RS-232 level translator IC. (RS-232 in should create TTL 
etc)

Does not explain why the OCXO remains stuck as if it was untrained.

I suspect that the CPU never starts or hangs early.

Cheers,
Magnus