On 08/30/2012 06:33 PM, Bob Camp wrote:
Hi
The fundamental / third approach is one of several possible ways to go. You
can also run an SC on the B and C modes to get thermometer data. Early
implementations used a pair of independent blanks, one cut to be a good
thermometer. Some have even gone as far as to mount a thermistor on the
crystal.
No matter what you do, it adds cost.
The reason for doing it is to lower powerconsumption in critical
applications.
Cheers,